Product Introduction
Model :TSC001D-150C
The large low humidity incubator uses the constant temperature and humidity control system, and uses PID to control SSR, so that the heating and humidification amount of the system is equal to the heat and humidity loss amount. From the dry and wet ball temperature measurement signal through A/D conversion input controller CPU and RAN output to the I/O board, I/O board issued instructions to make the air supply system and freezing system work, while PID control SSR or heating SSR work, or humidification SSR work, so that the heat and humidity through the air supply system uniform test box to achieve constant temperature and humidity regulation.
Instrument characteristics
Operation precautions:
1, the machine is absolutely prohibited to heat or test explosive, combustible and highly corrosive substances. Otherwise, it will cause unnecessary losses, or the machine can not be tested.
2, the amount of test object placement can not affect the air circulation of the test box, otherwise it will affect the machine performance.
3, when using the door to close, close tightly, otherwise the temperature and humidity leakage, can not reach the performance area.
4, designated personnel to operate this machine, so as to avoid early damage to the machine.
5, the machine is attached to the left side of the test hole, can be connected to the box test line use
6. When you want to observe the changes in the box during the test, you can turn on the lamp [door light switch] in the box and observe the changes of the samples in the box through the window.
7, if the machine is operating below 0℃, should try to avoid opening the door, because in the low temperature, the bitter opening of the door is easy to cause the internal evaporator and other parts of the ice sealing phenomenon, especially the lower the temperature, the more serious the situation
If it must be opened, the time should be as short as possible.
8, when the low temperature operation is completed, be sure to set the temperature condition of 60C for drying treatment about half an hour after opening the door, so as not to affect the measurement time of the next operating condition or the evaporator icing phenomenon or the test object damage. (If the machine fails due to the actual 60C drying treatment, it is also an error during the warranty period, and the company will not provide free service).
9, during the operation, unless absolutely necessary, please do not open the door, otherwise it may lead to the following adverse consequences:
It is very dangerous for high temperature and moisture to rush out of the box!
The inside of the door still maintains high temperature causing damage!
Hot air can trigger a fire alarm and cause misoperation!
Open the door method: When the operator opens the door, he must move backward in the direction of the door to prevent a large number of hot gases from pouring out of the machine.
10, please note that the machine must be safely grounded to avoid electrostatic induction!
11, circuit short-circuit device, temperature overtemperature protector, to provide the safety protection of the machine test products and operators, so please check regularly.
12, the correct device wet ball test cloth, square energy to take the correct relative humidity.
13, during operation, do not touch the hand to check, so as to avoid electric shock or injury to the fan, and the danger, so please stop the operation first, turn off the electricity and then repair.
14, non-local staff can not carry out maintenance and inspection of the machine, maintenance and inspection, by full-time personnel, while there must be guardianship, to prevent unaware personnel to pass the radio gate, resulting in electric shock
Hurting people.
15, please read the controller manual and related instructions before operating the machine.

specification

argument

Machine model TSC001-1000C

TSC001-1000C

Temperature range

-40℃---150℃

Humidity range

20—98%RH.

Temperature and humidity control accuracy

±0.5℃;±2.5%RH.

Uniform temperature and humidity distribution

±2.0℃;±3.0%R.H.

Heating time

From room temperature to 100 ° C, within 30 minutes (when unloaded).

Cooling time

From room temperature to -20 ° C, within 40 minutes (no more than 30 ° C when unloaded)

Box size

100x100x100cm(WxHxD)

Carton size

150x210x150cm(WxHxD)

Equipment placement space

At least 200x250x200cm(WxHxD)

Test chamber door

120x120cm(WxH), one fan in total

Power source

AC 3$ 4W 380V 50/60HZ MAX40A